All content on this site is intended for healthcare professionals only. By acknowledging this message and accessing the information on this website you are confirming that you are a healthcare professional.

  TRANSLATE

The SOT Hub website uses a third-party service provided by Google that dynamically translates web content. Translations are machine generated, so may not be an exact or complete translation, and the SOT Hub cannot guarantee the accuracy of translated content. The SOT Hub and its employees will not be liable for any direct, indirect, or consequential damages (even if foreseeable) resulting from use of the Google Translate feature. For further support with Google Translate, visit Google Translate Help.

The Solid Organ Transplantation Hub is an independent medical education platform, sponsored by Therakos. Funders are allowed no direct influence on our content. The levels of sponsorship listed are reflective of the amount of funding given. View funders.

Now you can support HCPs in making informed decisions for their patients

Your contribution helps us continuously deliver expertly curated content to HCPs worldwide. You will also have the opportunity to make a content suggestion for consideration and receive updates on the impact contributions are making to our content.

Find out more

Diagnostic accuracy of HEARTBiT for ACR after heart transplantation

By Megan Moore

Share:

Nov 24, 2026

Learning objective: After reading this article, learners will be able to cite a new clinical development in heart transplantation.


Results from a prospective, multicenter study (NCT03575910) validating the diagnostic accuracy of HEARTBiT, a nine-gene T-cell transcriptomic biomarker, for detecting moderate-to-severe acute cellular rejection (ACR) in 117 adult heart transplant recipients across 336 visits at four tertiary centers were published in European Heart Journal by Shannon et al. Diagnostic performance was assessed against centralized expert consensus panel endomyocardial biopsy (EMB) grades. The primary objective was to evaluate performance using the area under the receiver operating characteristic curve (AUC). 

Key data: HEARTBiT demonstrated an overall AUC of 0.78 (95% confidence interval [CI], 0.70–0.86) for detecting moderate-to-severe ACR. Diagnostic performance was consistent during the early post-transplant period (≤60 days; AUC, 0.78; 95% CI, 0.65–0.90) and beyond 60 days (AUC, 0.80; 95% CI, 0.72–0.87). Using the prespecified threshold (>0.54), sensitivity was 88.9% and specificity was 55.8% ≤60 days post-transplant, corresponding to a negative predictive value (NPV) of 99.3%. Beyond 60 days, sensitivity was 100% and specificity was 49.0% (NPV, 100%). 

Key learning: These findings suggest that HEARTBiT may provide a minimally invasive rule-out signal for moderate-to-severe ACR across the first year after heart transplantation, including the high-risk early post-operative period. Based on diagnostic performance, HEARTBiT could potentially spare more than 50% of protocol surveillance EMBs in the first year after transplant.

References

Please indicate your level of agreement with the following statements:

The content was clear and easy to understand

The content addressed the learning objectives

The content was relevant to my practice

I will change my clinical practice as a result of this content

This content is accurate as of the date of publication and is not updated retrospectively. Please refer to the latest available evidence, guidelines, and relevant regulatory information when making clinical decisions.

Your opinion matters

Which of the following additional evidence do you think would have the greatest impact on clinicians’ choice to adopt ECP in SOT?